Skip to content
← Sika / Industrial & Construction
Sika · Industrial & Construction

CTM ECTR

ECTR is a two component, glossy, 100% solids, low VOC, low odour, versatile water-clear epoxy resin.

CTM ECTR product image
CTM ECTR
THE MANUFACTURERSika

Protective coatings.
Local knowledge.

ChemistryEpoxy
ComponentsTwo-part
Mixing ratioClear and Factory Pre-tint A:B = 2:1 (by volume)
THE RIGHT START MATTERS

KNOW THE
SURFACE.
PLAN THE
COATING.

ECTR is a two component, glossy, 100% solids, low VOC, low odour, versatile water-clear epoxy resin.

Start with the surface, the existing finish and the way the space or equipment is used. Our team can help you work through product choices and the requirements for your project.

Get into the details
A workshop with a coated concrete floor
Project inspirationIllustrative project scene; not a documented installation of this product.
01 / CHECK

The surface.

Identify the material, its condition and the work you’re planning.

02 / PLAN

The system.

Confirm product suitability, preparation and compatibility with our team.

03 / CONFIRM

The conditions.

Check the current manufacturer instructions for application, installation or maintenance requirements.

PRODUCT SPECIFICATIONS

THE DETAILS.
ALL HERE.

Keep the technical information close.
Use the current manufacturer documents when planning the work.

Open the document centre
CTM ECTR product specifications
PackagingComponents A+B: 11.35 L (3 US gal) unit Component A:  7.57 L (2 US gal) Component B: 3.78 L (1 US gal)
APPROVALS / CERTIFICATESMeets the requirements of CFIA for use in food plants.
Shelf Life12 months in original unopened packaging.
Storage ConditionsStore in a dry place, protected from freezing at a temperature between 5 °C and 32 °C (41 °F and 90 °F).  Protect from freezing. If ECTR has frozen, contact Sika Canada.
Volatile organic compound (VOC) content< 25 g/L (Clear)
Shore D Hardness~85
Pull-Off Strength> 2.4 MPa (> 350 psi) (substrate failure)
Mixing RatioClear and Factory Pre-tint A:B = 2:1 (by volume)
Product TemperatureCondition product at temperatures between 18 °C to 30 °C (65 °F to 86 °F) before using and during the application.
Ambient Air TemperatureMinimum: 10 °C (50 °F) Maximum: 30 °C (85 °F) Note: Mixing and application attempted at material, ambient and/or substrate temperature conditions less than 18 °C (65 °F) will result in a decrease in product workability and slower cure rates.
Relative Air HumidityMaximum 85 % (during application and curing).
Dew PointSubstrate must be at least 3 ˚C (5 ˚F) above the Dew Point to reduce the risk of condensation, which may lead to adhesion failure or “blushing” on the floor finish. Be aware that the substrate temperature may be lower than the ambient temperature.
Substrate TemperatureMinimum:10 °C (50 °F) / Maximum : 30 °C (86 °F) Note: Any attempt to apply ECTR at substrate temperature conditions less than 18 °C (65 °F) will result in an increase in viscosity and slower cure rates.
Substrate Moisture ContentMoisture content of concrete substrate must be ≤ 4 % by mass (pbw – part by weight) as measured with a Tramex®CME / CMExpert type concrete moisture meter on mechanically prepared surface in accordance with the instructions specified in this product technical data sheet ( ICRI/CSP 3-4 ).
Pot LifeMaterial Temperature Time 23 °C (73 °F) ~55 minutes
Curing TimeSubstrate Temperature Tack Free Full Cure 23 °C (73 °F) ~8 hours ~7 days Note: Curing times may vary depending on the ambient temperature, the substrate temperature, and the relative humidity level. Freshly applied material should be protected from dampness, condensation, and water for at least 48 hours. Mechanical, chemical, and physical properties will be fully achieved at full cure.
ConsumptionSmooth Coating: Prime coat: (8 mil) 5 m 2 /L (203 ft 2 /US gal) Finish coat: (15 mil) 2.6 m 2 /L (106 ft 2 /US gal) Note: Actual coverage rates and material consumption will depend upon porosity and profile of substrates.  Test sections are recommended to establish correct coverage.
SUBSTRATE QUALITYConcrete surfaces must be clean and sound. The compressive strength of the concrete substrate should be at least 25 MPa (3625 psi) at 28 days and a minimum of 1.5 MPa (218 psi) in tensile strength, at the time of the application. Substrates must be free of contaminants such as dust, dirt, existing paint films, efflorescence, exudates, laitance, form, hydraulic or fuel oils, brake fluid, grease, fungi, mildew, biological residues or any other contaminants which may prohibit good bond or conditions of the substrate that may reduce the overall performances of ECTR.
APPLICATIONPrime Coat: Apply mixed ECTR as a prime coat onto the substrate using a brush, roller, or squeegee, at a uniform coverage without puddling. Wear Coat: Once the prime coat is tack-free, apply the wear coat using a brush, squeegee, and backroll to achieve even coverage. Notes: It is important to apply subsequent coats of this and other products within 48 hours (under normal curing conditions). If this coating is allowed to cure longer than the 48 hours before subsequent recoats. Refer to the Waiting Time / Overcoating on page 3 of this document for preparing the surface. The use of bright colours may require additional coats.
CLEAN UPClean all tools and equipment with a non-flammable solvent. Once hardened, product can only be removed mechanically.
Cure timeSubstrate Temperature Tack Free Full Cure 23 °C (73 °F) ~8 hours ~7 days
Application temperatureMinimum: 10 °C (50 °F)
VOC< 25 g/L (Clear)
THE DOCUMENT CENTRE

KNOW BEFORE
YOU COAT.

Technical information.
Safety information.
Ready when you need it.

Check the product label and current manufacturer documents for the exact component, colour and region before use.

Full product details, applications & manufacturer specifications

ECTR is a two component, glossy, 100% solids, low VOC, low odour, versatile water-clear epoxy resin.

It is also available as a factory pre-tinted product with a selection of high volume stock colours. ECTR can be applied as a smooth non-textured finish, or custom aggregate textured finish using very fine to aggressive coarse aggregates that improve traction values on wet or contaminated surfaces.

ECTR is typically used to protect new surfaces or restored existing deteriorated concrete floors It can be applied clear or pigmented, typically installed as a concrete primer, high-build smooth coating or as a binder for broadcast or trowel applied surfacing

Coverage

Smooth Coating: Prime coat: (8 mil) 5 m 2 /L (203 ft 2 /US gal) Finish coat: (15 mil) 2.6 m 2 /L (106 ft 2 /US gal) Note: Actual coverage rates and material consumption will depend upon porosity and profile of substrates.  Test sections are recommended to establish correct coverage.

Application method

Prime Coat: Apply mixed ECTR as a prime coat onto the substrate using a brush, roller, or squeegee, at a uniform coverage without puddling. Wear Coat: Once the prime coat is tack-free, apply the wear coat using a brush, squeegee, and backroll to achieve even coverage. Notes: It is important to apply subsequent coats of this and other products within 48 hours (under normal curing conditions). If this coating is allowed to cure longer than the 48 hours before subsequent recoats. Refer to the Waiting Time / Overcoating on page 3 of this document for preparing the surface. The use of bright colours may require additional coats.

Drying time

Curing Time: Substrate Temperature Tack Free Full Cure 23 °C (73 °F) ~8 hours ~7 days Note: Curing times may vary depending on the ambient temperature, the substrate temperature, and the relative humidity level. Freshly applied material should be protected from dampness, condensation, and water for at least 48 hours. Mechanical, chemical, and physical properties will be fully achieved at full cure.

Recoat time

Ambiant and Substrate Minimum Maximum Temperature 23 °C (73 °F) ~ 8 hours 48 hours

Use the sheet for your exact product code and finish. Coverage and times depend on the stated temperature, humidity, substrate and coat thickness.

Features

  • Excellent protection for new or restored concrete substrates
  • Glossy aesthetic finish.
  • Durable, impermeable, and seamless
  • Very good mechanical and chemical resistance
  • Easily cleaned and maintained
  • Low VOC / low odour suitable for application in occupied facilities
Packaging
Components A+B: 11.35 L (3 US gal) unit Component A:  7.57 L (2 US gal) Component B: 3.78 L (1 US gal)
APPROVALS / CERTIFICATES
Meets the requirements of CFIA for use in food plants.
Shelf Life
12 months in original unopened packaging.
Storage Conditions
Store in a dry place, protected from freezing at a temperature between 5 °C and 32 °C (41 °F and 90 °F).  Protect from freezing. If ECTR has frozen, contact Sika Canada.
Volatile organic compound (VOC) content
< 25 g/L (Clear)
Shore D Hardness
~85
Pull-Off Strength
> 2.4 MPa (> 350 psi) (substrate failure)
Mixing Ratio
Clear and Factory Pre-tint A:B = 2:1 (by volume)
Product Temperature
Condition product at temperatures between 18 °C to 30 °C (65 °F to 86 °F) before using and during the application.
Ambient Air Temperature
Minimum: 10 °C (50 °F) Maximum: 30 °C (85 °F) Note: Mixing and application attempted at material, ambient and/or substrate temperature conditions less than 18 °C (65 °F) will result in a decrease in product workability and slower cure rates.
Relative Air Humidity
Maximum 85 % (during application and curing).
Dew Point
Substrate must be at least 3 ˚C (5 ˚F) above the Dew Point to reduce the risk of condensation, which may lead to adhesion failure or “blushing” on the floor finish. Be aware that the substrate temperature may be lower than the ambient temperature.
Substrate Temperature
Minimum:10 °C (50 °F) / Maximum : 30 °C (86 °F) Note: Any attempt to apply ECTR at substrate temperature conditions less than 18 °C (65 °F) will result in an increase in viscosity and slower cure rates.
Substrate Moisture Content
Moisture content of concrete substrate must be ≤ 4 % by mass (pbw – part by weight) as measured with a Tramex®CME / CMExpert type concrete moisture meter on mechanically prepared surface in accordance with the instructions specified in this product technical data sheet ( ICRI/CSP 3-4 ).
Pot Life
Material Temperature Time 23 °C (73 °F) ~55 minutes
Curing Time
Substrate Temperature Tack Free Full Cure 23 °C (73 °F) ~8 hours ~7 days Note: Curing times may vary depending on the ambient temperature, the substrate temperature, and the relative humidity level. Freshly applied material should be protected from dampness, condensation, and water for at least 48 hours. Mechanical, chemical, and physical properties will be fully achieved at full cure.
Consumption
Smooth Coating: Prime coat: (8 mil) 5 m 2 /L (203 ft 2 /US gal) Finish coat: (15 mil) 2.6 m 2 /L (106 ft 2 /US gal) Note: Actual coverage rates and material consumption will depend upon porosity and profile of substrates.  Test sections are recommended to establish correct coverage.
SUBSTRATE QUALITY
Concrete surfaces must be clean and sound. The compressive strength of the concrete substrate should be at least 25 MPa (3625 psi) at 28 days and a minimum of 1.5 MPa (218 psi) in tensile strength, at the time of the application. Substrates must be free of contaminants such as dust, dirt, existing paint films, efflorescence, exudates, laitance, form, hydraulic or fuel oils, brake fluid, grease, fungi, mildew, biological residues or any other contaminants which may prohibit good bond or conditions of the substrate that may reduce the overall performances of ECTR.
APPLICATION
Prime Coat: Apply mixed ECTR as a prime coat onto the substrate using a brush, roller, or squeegee, at a uniform coverage without puddling. Wear Coat: Once the prime coat is tack-free, apply the wear coat using a brush, squeegee, and backroll to achieve even coverage. Notes: It is important to apply subsequent coats of this and other products within 48 hours (under normal curing conditions). If this coating is allowed to cure longer than the 48 hours before subsequent recoats. Refer to the Waiting Time / Overcoating on page 3 of this document for preparing the surface. The use of bright colours may require additional coats.
CLEAN UP
Clean all tools and equipment with a non-flammable solvent. Once hardened, product can only be removed mechanically.
Cure time
Substrate Temperature Tack Free Full Cure 23 °C (73 °F) ~8 hours ~7 days
Application temperature
Minimum: 10 °C (50 °F)
VOC
< 25 g/L (Clear)
COLOUR / FINISH / POSSIBILITIES

Colours &
finish options.

Explore the published colour and finish information for this product.

Water-clear / pretinted in White, Silver, Light Grey and Medium Grey

PRODUCT COLOUR COLLECTION

CTM ECTR colour options

5 of 5 references

Available clear or in the listed factory colours. For field tinting, use the current compatible Sika pigment-pack system.

  • Water-clear
  • White
  • Silver
  • Light Grey
  • Medium Grey
Official Epoxy Pigment Pack CA chart · Open PDF ↗
View the full product colour collection

Screen colours are approximate. Confirm your choice with a physical sample. Wood species, fabric opacity, preparation and the coating system can affect the result.

Explore related categories

SUPERIOR COATINGS / THUNDER BAY

BIG PROJECT?
LET’S TALK.

Share the surface, its condition and what it needs to stand up to. We’ll help you work through the product choices and preparation.

Ask about CTM ECTR
VISIT SUPERIOR COATINGS

Find us in Thunder Bay.

550 Fort William Road
Thunder Bay, Ontario

Call 807-345-4511 ↗

550 Fort William Road, Thunder Bay

Compare your products

Ask our team ↗

Swipe across to compare products. Detail labels stay visible.

Check official product documents and confirm suitability with our team.

YOUR IDEAS, TOGETHER

My Projects

YOUR PROJECTS, WHEREVER YOU ARE

Keep your plans close.

Create a free account to pick up your projects on another device. Your saved colours, products and notes come with you.

How saved projects and account information work (opens in a new tab)