Sikafloor®-219 UTE

Sikafloor®-219 UTE is a multi-functional, two-component, high solids, low VOC, low odour, clear epoxy resin that can be applied with or without Sikafloor® Epoxy Pigment Packs to create a variety of durable, decorative coating finishes.

Sikafloor®-219 UTE product image
Sikafloor®-219 UTE
THE MANUFACTURERSika

Protective coatings.
Local knowledge.

ChemistryEpoxy
ComponentsTwo-part
THE RIGHT START MATTERS

KNOW THE
SURFACE.
PLAN THE
COATING.

Sikafloor®-219 UTE is a multi-functional, two-component, high solids, low VOC, low odour, clear epoxy resin that can be applied with or without Sikafloor® Epoxy Pigment Packs to create a variety of durable, decorative coating finishes.

Start with the surface, the existing finish and the way the space or equipment is used. Our team can help you work through product choices and the requirements for your project.

Get into the details
A workshop with a coated concrete floor
Project inspirationIllustrative project scene; not a documented installation of this product.
01 / CHECK

The surface.

Identify the material, its condition and the work you’re planning.

02 / PLAN

The system.

Confirm product suitability, preparation and compatibility with our team.

03 / CONFIRM

The conditions.

Check the current manufacturer instructions for application, installation or maintenance requirements.

PRODUCT SPECIFICATIONS

THE DETAILS.
ALL HERE.

Keep the technical information close.
Use the current manufacturer documents when planning the work.

Open the document centre
Sikafloor®-219 UTE product specifications
PackagingNEW FORMULA Standard format: Components A+B: 11.35 L (3 US gal) Component A: 7.57 L (2 US gal) Component B: 3.78 L (1 US gal) Medium format: Components A+B: 28.35 L (7.5 US gal) Component A: 18.9 L (5 US gal) Component B: 9.45 L (2.5 US gal) IMPORTANT:  The components of this new formula ARE NOT compatible with the component from the previous formula.  A round sticker (purple) will appear on the packaging of the new formula to facilitate the transition.
APPROVALS / CERTIFICATESMeets the requirements of CFIA for use in food plants.
Shelf Life2 years in original unopened packaging
Storage ConditionsStore in a dry place, protected from freezing at a temperature between 5 °C and 32 °C (41 °F and 90 °F).  Protect from freezing. If Sikafloor®-219 UTE has frozen, contact Sika Canada.
Volatile organic compound (VOC) content~28 g/L
ViscosityA+B (Clear): ~500 cPs
Shore D Hardness~80 (ASTM D2240)
Abrasion Resistance~0.034 g loss: CS17 wheel /1000 cycles/1000 g (ASTM D4060)
Resistance to Impact~20.34 joules (~15.75 ft*lb) (ASTM D2794)
Tensile Strength~44 MPa (~6381 psi) (ASTM D638)
Pull-Off Strength> 2.5 MPa (363 psi) (substrate failure) (ASTM D7234)
Coefficient of Friction~0.43 Wet (smooth clear) ~0.44 Wet (smooth pigmented) (ANSI A326.3) DCOF - BOT 3000e
Service TemperatureMinimum ~0 °C (~32 °F) maximum ~50 °C (~122 °F)
Water Absorption~0.58% (24 hours) (ASTM D570)
Mixing RatioClear A:B = 2:1 (by volume) When tinting on site: Add 1 x 946 ml Sikafloor® Epoxy Pigment Pack CA into part A (7.57 L) of Sikafloor®-219 UTE for the standard format. Add 2 x 946 ml Sikafloor® Epoxy Pigment Pack CA into part A (18.9 L) of Sikafloor®-219 UTE for the medium format.
Product TemperatureCondition product at temperatures between 18 °C and 30 °C (65 °F and 86 °F) before using and during the application.
Ambient Air TemperatureMinimum: 10 °C (50 °F)  Maximum: 30 °C (86 °F) Note: Mixing carried out under conditions where the Sikafloor®-219 UTE temperature and ambient temperature are below 18°C (65°F) will result in reduced product workability and slower curing rates.
Relative Air HumidityMaximum 85 % (during application and curing).
Dew PointSubstrate must be at least 3 ˚C (5 ˚F) above the Dew Point to reduce the risk of condensation, which may lead to adhesion failure or “blushing” on the floor finish.  Be aware that the substrate temperature may be lower than the ambient temperature.
Substrate TemperatureMinimum: 10 °C (50 °F)  Maximum: 30 °C (86 °F) Note: Mixing and application attempted at material, ambient and /or substrate temperature conditions less than 18 °C (65 °F) will result in an increase of the viscosity of the Sikafloor®-219 UTE and slower cure rates.
Substrate Moisture ContentMoisture content of concrete substrate must be ≤ 4 % by mass (pbw – part by weight) as measured with a Tramex®CME / CMExpert type concrete moisture meter on mechanically prepared surface according to this product data sheet (preparation to ICRI / CSP 3 - 4).
Pot Life~25 minutes
Curing TimeAmbient & Substrate Temperature Foot Traffic Light Traffic Normal Traffic 10 °C (50 °F) ~48 hours ~4 days ~7 days 23 °C (73 °F) ~24 hours ~2 days ~5 days 30 °C (86 °F) ~16 hours ~36 hours ~4 days Note: Curing times will vary according to ambient air and substrate temperatures and relative humidity. Freshly applied material should be protected from dampness, condensation, and water for at least 72 hours following the end of the application.
ConsumptionSmooth Coating: (23 mil total thickness) As a primer: (8 mil) 5 m 2 /L (203 ft 2 /US gal) Wear coat: (15 mil) 2.6 m 2 /L (106 ft 2 /US gal) Note: Actual coverage rates and material consumption will depend upon the porosity and the profile of the substrate. Test sections are recommended to establish correct coverage.
SUBSTRATE QUALITYConcrete surfaces must be clean and sound. The compressive strength of the concrete substrate should be at least 25 MPa (3625 psi) at 28 days and a minimum of 1.5 MPa (217 psi) in tensile strength, at the time of the application. Substrates must be free of contaminants such as dust, dirt, existing paint films, efflorescence, exudates, laitance, form, hydraulic or fuel oils, brake fluid, grease, fungi, mildew, biological residues or any other contaminants which may prohibit good bond or conditions of the substrate that may reduce the overall performances of Sikafloor®-219 UTE.
APPLICATIONAs a primer: Apply Sikafloor®-219 UTE as a prime coat onto the substrate using a brush, roller or squeegee, at a uniform coverage without puddling. Wear Coat: Once the prime coat is tack-free, apply the wear coat using a squeegee or roller and backroll to achieve even coverage. Waiting Time / Overcoating: It is important to apply subsequent coats of this and other products within 48 hours (under normal curing conditions). If this coating is allowed to cure longer than the 48 hours before subsequent recoats. Refer to the Waiting Time / Overcoating on page 3 of this document for preparing the surface.
CLEAN UPClean all tools and equipment with a non-flammable solvent. Once hardened, product can only be removed mechanically.
Cure timeAmbient Foot Traffic Light Traffic Normal Traffic & Substrate Temperature 10 °C (50 °F) ~48 hours ~4 days ~7 days 23 °C (73 °F) ~24 hours ~2 days ~5 days 30 °C (86 °F) ~16 hours ~36 hours ~4 days
Application temperatureMinimum: 10 °C (50 °F) Maximum: 30 °C (86 °F)
VOC~28 g/L
THE DOCUMENT CENTRE

KNOW BEFORE
YOU COAT.

Technical information.
Safety information.
Ready when you need it.

Check the product label and current manufacturer documents for the exact component, colour and region before use.

Full product details, applications & manufacturer specifications

Sikafloor®-219 UTE is a multi-functional, two-component, high solids, low VOC, low odour, clear epoxy resin that can be applied with or without Sikafloor® Epoxy Pigment Packs to create a variety of durable, decorative coating finishes.

Sikafloor®-219 UTE is a universal epoxy resin system applied water or pigmented, typically installed as a   concrete primer, broadcast surfacing or trowel mortar binder and high-build coating.

Floors
Coverage

Smooth Coating: (23 mil total thickness) As a primer: (8 mil) 5 m 2 /L (203 ft 2 /US gal) Wear coat: (15 mil) 2.6 m 2 /L (106 ft 2 /US gal) Note: Actual coverage rates and material consumption will depend upon the porosity and the profile of the substrate. Test sections are recommended to establish correct coverage.

Application method

As a primer: Apply Sikafloor®-219 UTE as a prime coat onto the substrate using a brush, roller or squeegee, at a uniform coverage without puddling. Wear Coat: Once the prime coat is tack-free, apply the wear coat using a squeegee or roller and backroll to achieve even coverage. Waiting Time / Overcoating: It is important to apply subsequent coats of this and other products within 48 hours (under normal curing conditions). If this coating is allowed to cure longer than the 48 hours before subsequent recoats. Refer to the Waiting Time / Overcoating on page 3 of this document for preparing the surface.

Drying time

Curing Time: Ambient & Substrate Temperature Foot Traffic Light Traffic Normal Traffic 10 °C (50 °F) ~48 hours ~4 days ~7 days 23 °C (73 °F) ~24 hours ~2 days ~5 days 30 °C (86 °F) ~16 hours ~36 hours ~4 days Note: Curing times will vary according to ambient air and substrate temperatures and relative humidity. Freshly applied material should be protected from dampness, condensation, and water for at least 72 hours following the end of the application.

Recoat time

Ambient Minimum Maximum & Substrate Temperature 10 °C (50 °F) ~48 hours 96 hours 23 °C (73 °F) ~24 hours 48 hours 30 °C (86 °F) ~16 hours 36 hours

Use the sheet for your exact product code and finish. Coverage and times depend on the stated temperature, humidity, substrate and coat thickness.

Features

  • Excellent protection for new or old concrete and properly prepared steel surfaces
  • Glossy aesthetic finish
  • Durable, impermeable and seamless
  • Easily cleaned and maintained
  • Good mechanical resistance
  • Low-VOC content and low odour
Packaging
NEW FORMULA Standard format: Components A+B: 11.35 L (3 US gal) Component A: 7.57 L (2 US gal) Component B: 3.78 L (1 US gal) Medium format: Components A+B: 28.35 L (7.5 US gal) Component A: 18.9 L (5 US gal) Component B: 9.45 L (2.5 US gal) IMPORTANT:  The components of this new formula ARE NOT compatible with the component from the previous formula.  A round sticker (purple) will appear on the packaging of the new formula to facilitate the transition.
APPROVALS / CERTIFICATES
Meets the requirements of CFIA for use in food plants.
Shelf Life
2 years in original unopened packaging
Storage Conditions
Store in a dry place, protected from freezing at a temperature between 5 °C and 32 °C (41 °F and 90 °F).  Protect from freezing. If Sikafloor®-219 UTE has frozen, contact Sika Canada.
Volatile organic compound (VOC) content
~28 g/L
Viscosity
A+B (Clear): ~500 cPs
Shore D Hardness
~80 (ASTM D2240)
Abrasion Resistance
~0.034 g loss: CS17 wheel /1000 cycles/1000 g (ASTM D4060)
Resistance to Impact
~20.34 joules (~15.75 ft*lb) (ASTM D2794)
Tensile Strength
~44 MPa (~6381 psi) (ASTM D638)
Pull-Off Strength
> 2.5 MPa (363 psi) (substrate failure) (ASTM D7234)
Coefficient of Friction
~0.43 Wet (smooth clear) ~0.44 Wet (smooth pigmented) (ANSI A326.3) DCOF - BOT 3000e
Service Temperature
Minimum ~0 °C (~32 °F) maximum ~50 °C (~122 °F)
Water Absorption
~0.58% (24 hours) (ASTM D570)
Mixing Ratio
Clear A:B = 2:1 (by volume) When tinting on site: Add 1 x 946 ml Sikafloor® Epoxy Pigment Pack CA into part A (7.57 L) of Sikafloor®-219 UTE for the standard format. Add 2 x 946 ml Sikafloor® Epoxy Pigment Pack CA into part A (18.9 L) of Sikafloor®-219 UTE for the medium format.
Product Temperature
Condition product at temperatures between 18 °C and 30 °C (65 °F and 86 °F) before using and during the application.
Ambient Air Temperature
Minimum: 10 °C (50 °F)  Maximum: 30 °C (86 °F) Note: Mixing carried out under conditions where the Sikafloor®-219 UTE temperature and ambient temperature are below 18°C (65°F) will result in reduced product workability and slower curing rates.
Relative Air Humidity
Maximum 85 % (during application and curing).
Dew Point
Substrate must be at least 3 ˚C (5 ˚F) above the Dew Point to reduce the risk of condensation, which may lead to adhesion failure or “blushing” on the floor finish.  Be aware that the substrate temperature may be lower than the ambient temperature.
Substrate Temperature
Minimum: 10 °C (50 °F)  Maximum: 30 °C (86 °F) Note: Mixing and application attempted at material, ambient and /or substrate temperature conditions less than 18 °C (65 °F) will result in an increase of the viscosity of the Sikafloor®-219 UTE and slower cure rates.
Substrate Moisture Content
Moisture content of concrete substrate must be ≤ 4 % by mass (pbw – part by weight) as measured with a Tramex®CME / CMExpert type concrete moisture meter on mechanically prepared surface according to this product data sheet (preparation to ICRI / CSP 3 - 4).
Pot Life
~25 minutes
Curing Time
Ambient & Substrate Temperature Foot Traffic Light Traffic Normal Traffic 10 °C (50 °F) ~48 hours ~4 days ~7 days 23 °C (73 °F) ~24 hours ~2 days ~5 days 30 °C (86 °F) ~16 hours ~36 hours ~4 days Note: Curing times will vary according to ambient air and substrate temperatures and relative humidity. Freshly applied material should be protected from dampness, condensation, and water for at least 72 hours following the end of the application.
Consumption
Smooth Coating: (23 mil total thickness) As a primer: (8 mil) 5 m 2 /L (203 ft 2 /US gal) Wear coat: (15 mil) 2.6 m 2 /L (106 ft 2 /US gal) Note: Actual coverage rates and material consumption will depend upon the porosity and the profile of the substrate. Test sections are recommended to establish correct coverage.
SUBSTRATE QUALITY
Concrete surfaces must be clean and sound. The compressive strength of the concrete substrate should be at least 25 MPa (3625 psi) at 28 days and a minimum of 1.5 MPa (217 psi) in tensile strength, at the time of the application. Substrates must be free of contaminants such as dust, dirt, existing paint films, efflorescence, exudates, laitance, form, hydraulic or fuel oils, brake fluid, grease, fungi, mildew, biological residues or any other contaminants which may prohibit good bond or conditions of the substrate that may reduce the overall performances of Sikafloor®-219 UTE.
APPLICATION
As a primer: Apply Sikafloor®-219 UTE as a prime coat onto the substrate using a brush, roller or squeegee, at a uniform coverage without puddling. Wear Coat: Once the prime coat is tack-free, apply the wear coat using a squeegee or roller and backroll to achieve even coverage. Waiting Time / Overcoating: It is important to apply subsequent coats of this and other products within 48 hours (under normal curing conditions). If this coating is allowed to cure longer than the 48 hours before subsequent recoats. Refer to the Waiting Time / Overcoating on page 3 of this document for preparing the surface.
CLEAN UP
Clean all tools and equipment with a non-flammable solvent. Once hardened, product can only be removed mechanically.
Cure time
Ambient Foot Traffic Light Traffic Normal Traffic & Substrate Temperature 10 °C (50 °F) ~48 hours ~4 days ~7 days 23 °C (73 °F) ~24 hours ~2 days ~5 days 30 °C (86 °F) ~16 hours ~36 hours ~4 days
Application temperature
Minimum: 10 °C (50 °F) Maximum: 30 °C (86 °F)
VOC
~28 g/L
COLOUR / FINISH / POSSIBILITIES

Colours &
finish options.

Explore the published colour and finish information for this product.

Clear / tintable using Sikafloor® Epoxy Pigment Pack CA in: White, Silver, Light Grey, Medium Grey, Basalt Grey, Safety Yellow, Safety Red, Safety Blue & Safety Green. Refer to Sikafloor® Epoxy Pigment Pack CA chart

PRODUCT COLOUR COLLECTION

Sikafloor Epoxy Pigment Pack CA

8 of 9 references

Current Canadian pigment-pack chart for 219 UTE. The clear resin and pigment pack are separate components; confirm the current formula and dosage.

  • White
  • Silver
  • Light Grey
  • Medium Grey
  • Safety Yellow
  • Safety Red
  • Safety Blue
  • Safety Green
Official Epoxy Pigment Pack CA chart · Open PDF ↗
View the full product colour collection

Screen colours are approximate. Confirm your choice with a physical sample. Wood species, fabric opacity, preparation and the coating system can affect the result.

Complete your project.

Companion products for the selected product and system.

  • Coating Squeegee

    Spread the floor coating using the specified squeegee method.

    Select a squeegee blade suitable for the coating’s specified wet film and back-roll as directed by the Sika sheet. Control the material spread rate; a large-notched blade is not automatically suitable for a thin-film coating.

Explore related categories

SUPERIOR COATINGS / THUNDER BAY

BIG PROJECT?
LET’S TALK.

Share the surface, its condition and what it needs to stand up to. We’ll help you work through the product choices and preparation.

Ask about Sikafloor®-219 UTE
VISIT SUPERIOR COATINGS

Find us in Thunder Bay.

550 Fort William Road
Thunder Bay, Ontario

Call 807-345-4511 ↗

550 Fort William Road, Thunder Bay

Compare your products

Ask our team ↗

Swipe across to compare products. Detail labels stay visible.

Check official product documents and confirm suitability with our team.

YOUR IDEAS, TOGETHER

My Projects

YOUR PROJECTS, WHEREVER YOU ARE

Keep your plans close.

Create a free account to pick up your projects on another device. Your saved colours, products and notes come with you.

How saved projects and account information work (opens in a new tab)