Bar-Rust 236
Bar-Rust 236 is a high performance, multi-purpose, surface tolerant, two-component chemically-cured epoxy semi-gloss coating.


Protective coatings.
Local knowledge.
KNOW THE
SURFACE.
PLAN THE
COATING.
Bar-Rust 236 is a high performance, multi-purpose, surface tolerant, two-component chemically-cured epoxy semi-gloss coating.
Start with the surface, the existing finish and the way the space or equipment is used. Our team can help you work through product choices and the requirements for your project.
Get into the details
The surface.
Identify the material, its condition and the work you’re planning.
The system.
Confirm product suitability, preparation and compatibility with our team.
The conditions.
Check the current manufacturer instructions for application, installation or maintenance requirements.
THE DETAILS.
ALL HERE.
Keep the technical information close.
Use the current manufacturer documents when planning the work.
| Product type | Surface Tolerant-Surface Tolerant Epoxy |
|---|---|
| Product Chemistry | Surface Tolerant Epoxy |
| Volume Solids | 80 |
| VOC content (EPA method) | 170 g/lt |
| Colour Options | Off white,Ready Mix Colors |
| Maximum Dry film thickness | 200 |
| Minimum Dry film thickness | 100 |
| Number of components | Multi Pack |
| Chemistry | Epoxy |
| Components | Two-component |
| Mixing ratio | 4 part(s) : 1 part(s) by volume |
| Pot life | 23°F (-5°C) 41°F (5°C) 59°F (15°C) 77°F (25°C) 6 hours 6 hours 5 hours 4 hours |
| Film thickness | 4-8 mils (100-200 microns) dry equivalent to 5-10 mils (125-250 microns) wet |
| VOC | 1.41 lb/gal (170 g/lt) EPA Method 24 |
| Cleanup | Clean all equipment immediately after use with International GTA220 or International GTA610. It is good working practice to periodically flush out spray equipment during the course of the working day. Frequency of cleaning will depend upon amount sprayed, temperature and elapsed time, including any delays. |
| Thinning | International GTA220 or Not normally required. Maximum recommended thinning 10% International GTA610 |
KNOW BEFORE
YOU COAT.
Technical information.
Safety information.
Ready when you need it.
Bar-Rust
236
TDS · Bar-Rust 236 (en_US)
Read the full product requirements, application instructions and limitations.
SDS · Bar-Rust 236 · Part A Aluminium (Canada, English, 2019)
Product safety and handling information.
SDS · Bar-Rust 236 · Part A Medium Grey (Canada, English, 2019)
Product safety and handling information.
SDS · Bar-Rust 236 · Clear Part B (Canada, English, 2019)
Product safety and handling information.
Check the product label and current manufacturer documents for the exact component, colour and region before use.
Full product details, applications & manufacturer specifications
Bar-Rust 236 is a high performance, multi-purpose, surface tolerant, two-component chemically-cured epoxy semi-gloss coating.
Recommended uses
Industrial, Commercial.
Industrial coating- Finish
Semi-gloss
- Coverage
214 sq.ft/US gallon at 6 mils d.f.t and stated volume solids 5.30 m²/litre at 150 microns d.f.t and stated volume solids Allow appropriate loss factors
- Application method
Airless Spray, Air Spray, Brush, Roller
Use the sheet for your exact product code and finish. Coverage and times depend on the stated temperature, humidity, substrate and coat thickness.
Features
- Requires a two-component mixture.
- Product type
- Surface Tolerant-Surface Tolerant Epoxy
- Product Chemistry
- Surface Tolerant Epoxy
- Volume Solids
- 80
- VOC content (EPA method)
- 170 g/lt
- Colour Options
- Off white,Ready Mix Colors
- Maximum Dry film thickness
- 200
- Minimum Dry film thickness
- 100
- Number of components
- Multi Pack
- Chemistry
- Epoxy
- Components
- Two-component
- Mixing ratio
- 4 part(s) : 1 part(s) by volume
- Pot life
- 23°F (-5°C) 41°F (5°C) 59°F (15°C) 77°F (25°C) 6 hours 6 hours 5 hours 4 hours
- Film thickness
- 4-8 mils (100-200 microns) dry equivalent to 5-10 mils (125-250 microns) wet
- VOC
- 1.41 lb/gal (170 g/lt) EPA Method 24
- Cleanup
- Clean all equipment immediately after use with International GTA220 or International GTA610. It is good working practice to periodically flush out spray equipment during the course of the working day. Frequency of cleaning will depend upon amount sprayed, temperature and elapsed time, including any delays.
- Thinning
- International GTA220 or Not normally required. Maximum recommended thinning 10% International GTA610
Complete your project.
Companion products for the selected product and system.

Devprep 88
Clean aged epoxy, urethane or galvanized surfaces before coating.
Use where specified by the surface-preparation instructions; rinse thoroughly and complete the required mechanical preparation.

Pre-Prime 167
A penetrating sealer for specified rusty steel or concrete preparation.
Conditional preparation step. Confirm the substrate and full system; it does not replace the required rust removal or surface preparation.
Explore related categories
BIG PROJECT?
LET’S TALK.
Share the surface, its condition and what it needs to stand up to. We’ll help you work through the product choices and preparation.
Ask about Bar-Rust 236