Skip to content
← International / Industrial & Construction
International · Industrial & Construction

Bar-Rust 236

Bar-Rust 236 is a high performance, multi-purpose, surface tolerant, two-component chemically-cured epoxy semi-gloss coating.

Product illustration
Bar-Rust 236Product illustration
THE MANUFACTURERInternational

Protective coatings.
Local knowledge.

ChemistryEpoxy
ComponentsTwo-part
FinishSemi-gloss
Mixing ratio4 : 1 by volume
THE RIGHT START MATTERS

KNOW THE
SURFACE.
PLAN THE
COATING.

Bar-Rust 236 is a high performance, multi-purpose, surface tolerant, two-component chemically-cured epoxy semi-gloss coating.

Start with the surface, the existing finish and the way the space or equipment is used. Our team can help you work through product choices and the requirements for your project.

Get into the details
Bar-Rust 236 product image
A closer look at Bar-Rust 236Product image. Confirm the model, finish and current packaging with our team.
01 / CHECK

The surface.

Identify the material, its condition and the work you’re planning.

02 / PLAN

The system.

Confirm product suitability, preparation and compatibility with our team.

03 / CONFIRM

The conditions.

Check the current manufacturer instructions for application, installation or maintenance requirements.

PRODUCT SPECIFICATIONS

THE DETAILS.
ALL HERE.

Keep the technical information close.
Use the current manufacturer documents when planning the work.

Open the document centre
Bar-Rust 236 product specifications
Product typeSurface Tolerant-Surface Tolerant Epoxy
Product ChemistrySurface Tolerant Epoxy
Volume Solids80
VOC content (EPA method)170 g/lt
Colour OptionsOff white,Ready Mix Colors
Maximum Dry film thickness200
Minimum Dry film thickness100
Number of componentsMulti Pack
ChemistryEpoxy
ComponentsTwo-component
Mixing ratio4 part(s) : 1 part(s) by volume
Pot life23°F (-5°C) 41°F (5°C) 59°F (15°C) 77°F (25°C) 6 hours 6 hours 5 hours 4 hours
Film thickness4-8 mils (100-200 microns) dry equivalent to 5-10 mils (125-250 microns) wet
VOC1.41 lb/gal (170 g/lt) EPA Method 24
CleanupClean all equipment immediately after use with International GTA220 or International GTA610. It is good working practice to periodically flush out spray equipment during the course of the working day. Frequency of cleaning will depend upon amount sprayed, temperature and elapsed time, including any delays.
ThinningInternational GTA220 or Not normally required. Maximum recommended thinning 10% International GTA610
THE DOCUMENT CENTRE

KNOW BEFORE
YOU COAT.

Technical information.
Safety information.
Ready when you need it.

Check the product label and current manufacturer documents for the exact component, colour and region before use.

Full product details, applications & manufacturer specifications

Bar-Rust 236 is a high performance, multi-purpose, surface tolerant, two-component chemically-cured epoxy semi-gloss coating.

Industrial, Commercial.

Industrial coating
Finish

Semi-gloss

Coverage

214 sq.ft/US gallon at 6 mils d.f.t and stated volume solids 5.30 m²/litre at 150 microns d.f.t and stated volume solids Allow appropriate loss factors

Application method

Airless Spray, Air Spray, Brush, Roller

Use the sheet for your exact product code and finish. Coverage and times depend on the stated temperature, humidity, substrate and coat thickness.

Features

  • Requires a two-component mixture.
Product type
Surface Tolerant-Surface Tolerant Epoxy
Product Chemistry
Surface Tolerant Epoxy
Volume Solids
80
VOC content (EPA method)
170 g/lt
Colour Options
Off white,Ready Mix Colors
Maximum Dry film thickness
200
Minimum Dry film thickness
100
Number of components
Multi Pack
Chemistry
Epoxy
Components
Two-component
Mixing ratio
4 part(s) : 1 part(s) by volume
Pot life
23°F (-5°C) 41°F (5°C) 59°F (15°C) 77°F (25°C) 6 hours 6 hours 5 hours 4 hours
Film thickness
4-8 mils (100-200 microns) dry equivalent to 5-10 mils (125-250 microns) wet
VOC
1.41 lb/gal (170 g/lt) EPA Method 24
Cleanup
Clean all equipment immediately after use with International GTA220 or International GTA610. It is good working practice to periodically flush out spray equipment during the course of the working day. Frequency of cleaning will depend upon amount sprayed, temperature and elapsed time, including any delays.
Thinning
International GTA220 or Not normally required. Maximum recommended thinning 10% International GTA610

Complete your project.

Companion products for the selected product and system.

  • Devprep 88

    Clean aged epoxy, urethane or galvanized surfaces before coating.

    Use where specified by the surface-preparation instructions; rinse thoroughly and complete the required mechanical preparation.

  • Pre-Prime 167

    A penetrating sealer for specified rusty steel or concrete preparation.

    Conditional preparation step. Confirm the substrate and full system; it does not replace the required rust removal or surface preparation.

Explore related categories

SUPERIOR COATINGS / THUNDER BAY

BIG PROJECT?
LET’S TALK.

Share the surface, its condition and what it needs to stand up to. We’ll help you work through the product choices and preparation.

Ask about Bar-Rust 236
VISIT SUPERIOR COATINGS

Find us in Thunder Bay.

550 Fort William Road
Thunder Bay, Ontario

Call 807-345-4511 ↗

550 Fort William Road, Thunder Bay

Compare your products

Ask our team ↗

Swipe across to compare products. Detail labels stay visible.

Check official product documents and confirm suitability with our team.

YOUR IDEAS, TOGETHER

My Projects

YOUR PROJECTS, WHEREVER YOU ARE

Keep your plans close.

Create a free account to pick up your projects on another device. Your saved colours, products and notes come with you.

How saved projects and account information work (opens in a new tab)