Interseal 670HS Low Temperature
A low VOC, two component high build, high solids surface tolerant epoxy maintenance coating. Specially designed with an enhanced curing profile to maximise productivity in cold conditions.


Good products.
Local knowledge.
KNOW THE
PROJECT.
PLAN THE
DETAILS.
A low VOC, two component high build, high solids surface tolerant epoxy maintenance coating. Specially designed with an enhanced curing profile to maximise productivity in cold conditions.
Start with the surface, the existing finish and the way the space or equipment is used. Our team can help you work through product choices and the requirements for your project.
Get into the details
The project.
Identify the material, its condition and the work you’re planning.
The system.
Confirm product suitability, preparation and compatibility with our team.
The conditions.
Check the current manufacturer instructions for application, installation or maintenance requirements.
THE DETAILS.
ALL HERE.
Keep the technical information close.
Use the current manufacturer documents when planning the work.
| Product type | Surface Tolerant-Surface Tolerant Epoxy |
|---|---|
| Product Chemistry | Surface Tolerant Epoxy |
| Volume Solids | 82 |
| VOC content (EPA method) | 240 g/lt |
| Colour Options | Available on Chromascan |
| Maximum Dry film thickness | 250 |
| Minimum Dry film thickness | 100 |
| Number of components | Multi Pack |
| Chemistry | Epoxy |
| Components | Two-component |
| Mixing ratio | 5.67 part(s): 1 part(s) by volume |
| Pot life | 41°F (5°C) 50°F (10°C) 4 hours 3 hours |
| Film thickness | 4-10 mils (100-250 microns) dry equivalent to 4.9-12.2 mils (122-305 microns) wet |
| VOC | 2.00 lb/gal (240 g/lt) EPA Method 24 |
| Cleanup | Clean all equipment immediately after use with International GTA822. It is good working practice to periodically flush out spray equipment during the course of the working day. Frequency of cleaning will depend upon amount sprayed, temperature and elapsed time, including any delays. |
| Thinning | International GTA220 |
KNOW BEFORE
YOU START.
Technical information.
Safety information.
Ready when you need it.
Interseal 670HS Low Temperature
TDS · Interseal 670HS Low Temperature (en_US)
Read the full product requirements, application instructions and limitations.
MSDS · INTERSEAL 670HS ALUMINIUM PART A (en_CA)
Product safety and handling information.
MSDS · INTERSEAL 670HS BLACK PART A (en_CA)
Product safety and handling information.
MSDS · INTERSEAL 670HS WHITE PART A (en_CA)
Product safety and handling information.
MSDS · INTERSEAL 670HS PART B LOW TEMPERATURE (en_CA)
Product safety and handling information.
MSDS · INTERSEAL 670HS BUFF PART A (en_CA)
Product safety and handling information.
MSDS · INTERSEAL 670HS RED PART A (en_CA)
Product safety and handling information.
MSDS · INTERSEAL 670HS BASE ULTRA DEEP PART A (en_CA)
Product safety and handling information.
MSDS · INTERSEAL 670HS BASE LIGHT PART A (en_CA)
Product safety and handling information.
MSDS · INTERSEAL 670HS BASE YELLOW PART A (en_CA)
Product safety and handling information.
MSDS · INTERSEAL 670HS PEARL GREY PART A (en_CA)
Product safety and handling information.
MSDS · INTERSEAL 670HS ALUMINIUM PART A (en_US)
Product safety and handling information.
MSDS · INTERSEAL 670HS BLACK PART A (en_US)
Product safety and handling information.
MSDS · INTERSEAL 670HS WHITE PART A (en_US)
Product safety and handling information.
MSDS · INTERSEAL 670HS PART B LOW TEMPERATURE (en_US)
Product safety and handling information.
MSDS · INTERSEAL 670HS BUFF PART A (en_US)
Product safety and handling information.
MSDS · INTERSEAL 670HS RED PART A (en_US)
Product safety and handling information.
MSDS · INTERSEAL 670HS BASE ULTRA DEEP PART A (en_US)
Product safety and handling information.
MSDS · INTERSEAL 670HS BASE LIGHT PART A (en_US)
Product safety and handling information.
MSDS · INTERSEAL 670HS BASE YELLOW PART A (en_US)
Product safety and handling information.
MSDS · INTERSEAL 670HS RAL1021 YELLOW PART A (en_US)
Product safety and handling information.
MSDS · INTERSEAL 670HS PEARL GREY PART A (en_US)
Product safety and handling information.
Check the product label and current manufacturer documents for the exact component, colour and region before use.
Full product details, applications & manufacturer specifications
A low VOC, two component high build, high solids surface tolerant epoxy maintenance coating. Specially designed with an enhanced curing profile to maximise productivity in cold conditions.
Recommended uses
Exterior decks, Marine, Industrial, Commercial.
Industrial coating- Finish
Semi Gloss (Aluminum is eggshell)
- Coverage
263 sq.ft/US gallon at 5 mils d.f.t and stated volume solids 6.56 m²/litre at 125 microns d.f.t and stated volume solids Allow appropriate loss factors
- Application method
Airless Spray, Air spray, Brush, Roller can be used. Consult
- Drying time
23°F (-5°C): Touch dry 24 hours; hard/handle dry 72 hours 32°F (0°C): Touch dry 16 hours; hard/handle dry 56 hours 41°F (5°C): Touch dry 9 hours; hard/handle dry 36 hours 50°F (10°C): Touch dry 5 hours; hard/handle dry 24 hours
- Recoat time
23°F (-5°C): Minimum 72 hours; maximum 12 weeks¹ 32°F (0°C): Minimum 56 hours; maximum 10 weeks¹ 41°F (5°C): Minimum 36 hours; maximum 8 weeks¹ 50°F (10°C): Minimum 24 hours; maximum 6 weeks¹
Use the sheet for your exact product code and finish. Coverage and times depend on the stated temperature, humidity, substrate and coat thickness.
Features
- Requires a two-component mixture.
- Manufacturer identifies a low-VOC formulation.
- Product type
- Surface Tolerant-Surface Tolerant Epoxy
- Product Chemistry
- Surface Tolerant Epoxy
- Volume Solids
- 82
- VOC content (EPA method)
- 240 g/lt
- Colour Options
- Available on Chromascan
- Maximum Dry film thickness
- 250
- Minimum Dry film thickness
- 100
- Number of components
- Multi Pack
- Chemistry
- Epoxy
- Components
- Two-component
- Mixing ratio
- 5.67 part(s): 1 part(s) by volume
- Pot life
- 41°F (5°C) 50°F (10°C) 4 hours 3 hours
- Film thickness
- 4-10 mils (100-250 microns) dry equivalent to 4.9-12.2 mils (122-305 microns) wet
- VOC
- 2.00 lb/gal (240 g/lt) EPA Method 24
- Cleanup
- Clean all equipment immediately after use with International GTA822. It is good working practice to periodically flush out spray equipment during the course of the working day. Frequency of cleaning will depend upon amount sprayed, temperature and elapsed time, including any delays.
- Thinning
- International GTA220
Explore related categories
BIG PROJECT?
LET’S TALK.
Share the surface, its condition and what it needs to stand up to. We’ll help you work through the product choices and preparation.
Ask about Interseal 670HS Low Temperature