Sikafloor®-219 UTE
Sikafloor®-219 UTE is a multi-functional, two-component, high solids, low VOC, low odour, clear epoxy resin that can be applied with or without Sikafloor® Epoxy Pigment Packs to create a variety of durable, decorative coating finishes.


Protective coatings.
Local knowledge.
KNOW THE
SURFACE.
PLAN THE
COATING.
Sikafloor®-219 UTE is a multi-functional, two-component, high solids, low VOC, low odour, clear epoxy resin that can be applied with or without Sikafloor® Epoxy Pigment Packs to create a variety of durable, decorative coating finishes.
Start with the surface, the existing finish and the way the space or equipment is used. Our team can help you work through product choices and the requirements for your project.
Get into the details
The surface.
Identify the material, its condition and the work you’re planning.
The system.
Confirm product suitability, preparation and compatibility with our team.
The conditions.
Check the current manufacturer instructions for application, installation or maintenance requirements.
THE DETAILS.
ALL HERE.
Keep the technical information close.
Use the current manufacturer documents when planning the work.
| Packaging | NEW FORMULA Standard format: Components A+B: 11.35 L (3 US gal) Component A: 7.57 L (2 US gal) Component B: 3.78 L (1 US gal) Medium format: Components A+B: 28.35 L (7.5 US gal) Component A: 18.9 L (5 US gal) Component B: 9.45 L (2.5 US gal) IMPORTANT: The components of this new formula ARE NOT compatible with the component from the previous formula. A round sticker (purple) will appear on the packaging of the new formula to facilitate the transition. |
|---|---|
| APPROVALS / CERTIFICATES | Meets the requirements of CFIA for use in food plants. |
| Shelf Life | 2 years in original unopened packaging |
| Storage Conditions | Store in a dry place, protected from freezing at a temperature between 5 °C and 32 °C (41 °F and 90 °F). Protect from freezing. If Sikafloor®-219 UTE has frozen, contact Sika Canada. |
| Volatile organic compound (VOC) content | ~28 g/L |
| Viscosity | A+B (Clear): ~500 cPs |
| Shore D Hardness | ~80 (ASTM D2240) |
| Abrasion Resistance | ~0.034 g loss: CS17 wheel /1000 cycles/1000 g (ASTM D4060) |
| Resistance to Impact | ~20.34 joules (~15.75 ft*lb) (ASTM D2794) |
| Tensile Strength | ~44 MPa (~6381 psi) (ASTM D638) |
| Pull-Off Strength | > 2.5 MPa (363 psi) (substrate failure) (ASTM D7234) |
| Coefficient of Friction | ~0.43 Wet (smooth clear) ~0.44 Wet (smooth pigmented) (ANSI A326.3) DCOF - BOT 3000e |
| Service Temperature | Minimum ~0 °C (~32 °F) maximum ~50 °C (~122 °F) |
| Water Absorption | ~0.58% (24 hours) (ASTM D570) |
| Mixing Ratio | Clear A:B = 2:1 (by volume) When tinting on site: Add 1 x 946 ml Sikafloor® Epoxy Pigment Pack CA into part A (7.57 L) of Sikafloor®-219 UTE for the standard format. Add 2 x 946 ml Sikafloor® Epoxy Pigment Pack CA into part A (18.9 L) of Sikafloor®-219 UTE for the medium format. |
| Product Temperature | Condition product at temperatures between 18 °C and 30 °C (65 °F and 86 °F) before using and during the application. |
| Ambient Air Temperature | Minimum: 10 °C (50 °F) Maximum: 30 °C (86 °F) Note: Mixing carried out under conditions where the Sikafloor®-219 UTE temperature and ambient temperature are below 18°C (65°F) will result in reduced product workability and slower curing rates. |
| Relative Air Humidity | Maximum 85 % (during application and curing). |
| Dew Point | Substrate must be at least 3 ˚C (5 ˚F) above the Dew Point to reduce the risk of condensation, which may lead to adhesion failure or “blushing” on the floor finish. Be aware that the substrate temperature may be lower than the ambient temperature. |
| Substrate Temperature | Minimum: 10 °C (50 °F) Maximum: 30 °C (86 °F) Note: Mixing and application attempted at material, ambient and /or substrate temperature conditions less than 18 °C (65 °F) will result in an increase of the viscosity of the Sikafloor®-219 UTE and slower cure rates. |
| Substrate Moisture Content | Moisture content of concrete substrate must be ≤ 4 % by mass (pbw – part by weight) as measured with a Tramex®CME / CMExpert type concrete moisture meter on mechanically prepared surface according to this product data sheet (preparation to ICRI / CSP 3 - 4). |
| Pot Life | ~25 minutes |
| Curing Time | Ambient & Substrate Temperature Foot Traffic Light Traffic Normal Traffic 10 °C (50 °F) ~48 hours ~4 days ~7 days 23 °C (73 °F) ~24 hours ~2 days ~5 days 30 °C (86 °F) ~16 hours ~36 hours ~4 days Note: Curing times will vary according to ambient air and substrate temperatures and relative humidity. Freshly applied material should be protected from dampness, condensation, and water for at least 72 hours following the end of the application. |
| Consumption | Smooth Coating: (23 mil total thickness) As a primer: (8 mil) 5 m 2 /L (203 ft 2 /US gal) Wear coat: (15 mil) 2.6 m 2 /L (106 ft 2 /US gal) Note: Actual coverage rates and material consumption will depend upon the porosity and the profile of the substrate. Test sections are recommended to establish correct coverage. |
| SUBSTRATE QUALITY | Concrete surfaces must be clean and sound. The compressive strength of the concrete substrate should be at least 25 MPa (3625 psi) at 28 days and a minimum of 1.5 MPa (217 psi) in tensile strength, at the time of the application. Substrates must be free of contaminants such as dust, dirt, existing paint films, efflorescence, exudates, laitance, form, hydraulic or fuel oils, brake fluid, grease, fungi, mildew, biological residues or any other contaminants which may prohibit good bond or conditions of the substrate that may reduce the overall performances of Sikafloor®-219 UTE. |
| APPLICATION | As a primer: Apply Sikafloor®-219 UTE as a prime coat onto the substrate using a brush, roller or squeegee, at a uniform coverage without puddling. Wear Coat: Once the prime coat is tack-free, apply the wear coat using a squeegee or roller and backroll to achieve even coverage. Waiting Time / Overcoating: It is important to apply subsequent coats of this and other products within 48 hours (under normal curing conditions). If this coating is allowed to cure longer than the 48 hours before subsequent recoats. Refer to the Waiting Time / Overcoating on page 3 of this document for preparing the surface. |
| CLEAN UP | Clean all tools and equipment with a non-flammable solvent. Once hardened, product can only be removed mechanically. |
| Cure time | Ambient Foot Traffic Light Traffic Normal Traffic & Substrate Temperature 10 °C (50 °F) ~48 hours ~4 days ~7 days 23 °C (73 °F) ~24 hours ~2 days ~5 days 30 °C (86 °F) ~16 hours ~36 hours ~4 days |
| Application temperature | Minimum: 10 °C (50 °F) Maximum: 30 °C (86 °F) |
| VOC | ~28 g/L |
KNOW BEFORE
YOU COAT.
Technical information.
Safety information.
Ready when you need it.
Sikafloor®-219 UTE
Product Data Sheet (PDS) · Sikafloor®-219 UTE
Read the full product requirements, application instructions and limitations.
Technical data sheet – Colour Chart - Construction · Sikafloor® Epoxy Pigment Pack CA Colour Chart
Read the full product requirements, application instructions and limitations.
Safety Data Sheet (SDS) · SDS Sikafloor®-219 UTE Part A
Product safety and handling information.
Safety Data Sheet (SDS) · SDS Sikafloor®-219 UTE Part B
Product safety and handling information.
Colour Chart - Construction · Sikafloor®-219 UTE
Read the manufacturer’s instructions and product information.
Check the product label and current manufacturer documents for the exact component, colour and region before use.
Full product details, applications & manufacturer specifications
Sikafloor®-219 UTE is a multi-functional, two-component, high solids, low VOC, low odour, clear epoxy resin that can be applied with or without Sikafloor® Epoxy Pigment Packs to create a variety of durable, decorative coating finishes.
Recommended uses
Sikafloor®-219 UTE is a universal epoxy resin system applied water or pigmented, typically installed as a concrete primer, broadcast surfacing or trowel mortar binder and high-build coating.
Floors- Coverage
Smooth Coating: (23 mil total thickness) As a primer: (8 mil) 5 m 2 /L (203 ft 2 /US gal) Wear coat: (15 mil) 2.6 m 2 /L (106 ft 2 /US gal) Note: Actual coverage rates and material consumption will depend upon the porosity and the profile of the substrate. Test sections are recommended to establish correct coverage.
- Application method
As a primer: Apply Sikafloor®-219 UTE as a prime coat onto the substrate using a brush, roller or squeegee, at a uniform coverage without puddling. Wear Coat: Once the prime coat is tack-free, apply the wear coat using a squeegee or roller and backroll to achieve even coverage. Waiting Time / Overcoating: It is important to apply subsequent coats of this and other products within 48 hours (under normal curing conditions). If this coating is allowed to cure longer than the 48 hours before subsequent recoats. Refer to the Waiting Time / Overcoating on page 3 of this document for preparing the surface.
- Drying time
Curing Time: Ambient & Substrate Temperature Foot Traffic Light Traffic Normal Traffic 10 °C (50 °F) ~48 hours ~4 days ~7 days 23 °C (73 °F) ~24 hours ~2 days ~5 days 30 °C (86 °F) ~16 hours ~36 hours ~4 days Note: Curing times will vary according to ambient air and substrate temperatures and relative humidity. Freshly applied material should be protected from dampness, condensation, and water for at least 72 hours following the end of the application.
- Recoat time
Ambient Minimum Maximum & Substrate Temperature 10 °C (50 °F) ~48 hours 96 hours 23 °C (73 °F) ~24 hours 48 hours 30 °C (86 °F) ~16 hours 36 hours
Use the sheet for your exact product code and finish. Coverage and times depend on the stated temperature, humidity, substrate and coat thickness.
Features
- Excellent protection for new or old concrete and properly prepared steel surfaces
- Glossy aesthetic finish
- Durable, impermeable and seamless
- Easily cleaned and maintained
- Good mechanical resistance
- Low-VOC content and low odour
- Packaging
- NEW FORMULA Standard format: Components A+B: 11.35 L (3 US gal) Component A: 7.57 L (2 US gal) Component B: 3.78 L (1 US gal) Medium format: Components A+B: 28.35 L (7.5 US gal) Component A: 18.9 L (5 US gal) Component B: 9.45 L (2.5 US gal) IMPORTANT: The components of this new formula ARE NOT compatible with the component from the previous formula. A round sticker (purple) will appear on the packaging of the new formula to facilitate the transition.
- APPROVALS / CERTIFICATES
- Meets the requirements of CFIA for use in food plants.
- Shelf Life
- 2 years in original unopened packaging
- Storage Conditions
- Store in a dry place, protected from freezing at a temperature between 5 °C and 32 °C (41 °F and 90 °F). Protect from freezing. If Sikafloor®-219 UTE has frozen, contact Sika Canada.
- Volatile organic compound (VOC) content
- ~28 g/L
- Viscosity
- A+B (Clear): ~500 cPs
- Shore D Hardness
- ~80 (ASTM D2240)
- Abrasion Resistance
- ~0.034 g loss: CS17 wheel /1000 cycles/1000 g (ASTM D4060)
- Resistance to Impact
- ~20.34 joules (~15.75 ft*lb) (ASTM D2794)
- Tensile Strength
- ~44 MPa (~6381 psi) (ASTM D638)
- Pull-Off Strength
- > 2.5 MPa (363 psi) (substrate failure) (ASTM D7234)
- Coefficient of Friction
- ~0.43 Wet (smooth clear) ~0.44 Wet (smooth pigmented) (ANSI A326.3) DCOF - BOT 3000e
- Service Temperature
- Minimum ~0 °C (~32 °F) maximum ~50 °C (~122 °F)
- Water Absorption
- ~0.58% (24 hours) (ASTM D570)
- Mixing Ratio
- Clear A:B = 2:1 (by volume) When tinting on site: Add 1 x 946 ml Sikafloor® Epoxy Pigment Pack CA into part A (7.57 L) of Sikafloor®-219 UTE for the standard format. Add 2 x 946 ml Sikafloor® Epoxy Pigment Pack CA into part A (18.9 L) of Sikafloor®-219 UTE for the medium format.
- Product Temperature
- Condition product at temperatures between 18 °C and 30 °C (65 °F and 86 °F) before using and during the application.
- Ambient Air Temperature
- Minimum: 10 °C (50 °F) Maximum: 30 °C (86 °F) Note: Mixing carried out under conditions where the Sikafloor®-219 UTE temperature and ambient temperature are below 18°C (65°F) will result in reduced product workability and slower curing rates.
- Relative Air Humidity
- Maximum 85 % (during application and curing).
- Dew Point
- Substrate must be at least 3 ˚C (5 ˚F) above the Dew Point to reduce the risk of condensation, which may lead to adhesion failure or “blushing” on the floor finish. Be aware that the substrate temperature may be lower than the ambient temperature.
- Substrate Temperature
- Minimum: 10 °C (50 °F) Maximum: 30 °C (86 °F) Note: Mixing and application attempted at material, ambient and /or substrate temperature conditions less than 18 °C (65 °F) will result in an increase of the viscosity of the Sikafloor®-219 UTE and slower cure rates.
- Substrate Moisture Content
- Moisture content of concrete substrate must be ≤ 4 % by mass (pbw – part by weight) as measured with a Tramex®CME / CMExpert type concrete moisture meter on mechanically prepared surface according to this product data sheet (preparation to ICRI / CSP 3 - 4).
- Pot Life
- ~25 minutes
- Curing Time
- Ambient & Substrate Temperature Foot Traffic Light Traffic Normal Traffic 10 °C (50 °F) ~48 hours ~4 days ~7 days 23 °C (73 °F) ~24 hours ~2 days ~5 days 30 °C (86 °F) ~16 hours ~36 hours ~4 days Note: Curing times will vary according to ambient air and substrate temperatures and relative humidity. Freshly applied material should be protected from dampness, condensation, and water for at least 72 hours following the end of the application.
- Consumption
- Smooth Coating: (23 mil total thickness) As a primer: (8 mil) 5 m 2 /L (203 ft 2 /US gal) Wear coat: (15 mil) 2.6 m 2 /L (106 ft 2 /US gal) Note: Actual coverage rates and material consumption will depend upon the porosity and the profile of the substrate. Test sections are recommended to establish correct coverage.
- SUBSTRATE QUALITY
- Concrete surfaces must be clean and sound. The compressive strength of the concrete substrate should be at least 25 MPa (3625 psi) at 28 days and a minimum of 1.5 MPa (217 psi) in tensile strength, at the time of the application. Substrates must be free of contaminants such as dust, dirt, existing paint films, efflorescence, exudates, laitance, form, hydraulic or fuel oils, brake fluid, grease, fungi, mildew, biological residues or any other contaminants which may prohibit good bond or conditions of the substrate that may reduce the overall performances of Sikafloor®-219 UTE.
- APPLICATION
- As a primer: Apply Sikafloor®-219 UTE as a prime coat onto the substrate using a brush, roller or squeegee, at a uniform coverage without puddling. Wear Coat: Once the prime coat is tack-free, apply the wear coat using a squeegee or roller and backroll to achieve even coverage. Waiting Time / Overcoating: It is important to apply subsequent coats of this and other products within 48 hours (under normal curing conditions). If this coating is allowed to cure longer than the 48 hours before subsequent recoats. Refer to the Waiting Time / Overcoating on page 3 of this document for preparing the surface.
- CLEAN UP
- Clean all tools and equipment with a non-flammable solvent. Once hardened, product can only be removed mechanically.
- Cure time
- Ambient Foot Traffic Light Traffic Normal Traffic & Substrate Temperature 10 °C (50 °F) ~48 hours ~4 days ~7 days 23 °C (73 °F) ~24 hours ~2 days ~5 days 30 °C (86 °F) ~16 hours ~36 hours ~4 days
- Application temperature
- Minimum: 10 °C (50 °F) Maximum: 30 °C (86 °F)
- VOC
- ~28 g/L
Colours &
finish options.
Explore the published colour and finish information for this product.
Clear / tintable using Sikafloor® Epoxy Pigment Pack CA in: White, Silver, Light Grey, Medium Grey, Basalt Grey, Safety Yellow, Safety Red, Safety Blue & Safety Green. Refer to Sikafloor® Epoxy Pigment Pack CA chart
Sikafloor Epoxy Pigment Pack CA
Current Canadian pigment-pack chart for 219 UTE. The clear resin and pigment pack are separate components; confirm the current formula and dosage.
- White
- Silver
- Light Grey
- Medium Grey
- Safety Yellow
- Safety Red
- Safety Blue
- Safety Green
Screen colours are approximate. Confirm your choice with a physical sample. Wood species, fabric opacity, preparation and the coating system can affect the result.
Complete your project.
Companion products for the selected product and system.

Coating Squeegee
Spread the floor coating using the specified squeegee method.
Select a squeegee blade suitable for the coating’s specified wet film and back-roll as directed by the Sika sheet. Control the material spread rate; a large-notched blade is not automatically suitable for a thin-film coating.
Explore related categories
BIG PROJECT?
LET’S TALK.
Share the surface, its condition and what it needs to stand up to. We’ll help you work through the product choices and preparation.
Ask about Sikafloor®-219 UTE